Direct-to-Chip Cooling for Data Centers

Direct liquid cooling technology for your data center.

Direct to Chip Liquid Cooling for CPUs and GPUs

AI and high-performance computing (HPC) workloads are generating unprecedented heat in data centers, with processors at risk of throttling by 25% or more without adequate cooling. Traditional air-based methods are struggling to keep up — which is why more operators are turning to Direct-to-Chip (DTC) liquid cooling.

Direct-to-chip cooling is an advanced data center liquid cooling method that applies coolant directly to the server components that generate the most heat including CPUs and GPUs.

direct to chip cooling effectiveness vs air cooling

Data Center Challenges

  • direct liquid cooling companies icon
    Data Center Space
    • More computing power requires more hardware. Many IT teams are are finding that they are running out of space in their data centers.
  • direct to chip energy savings icon
    Energy Costs
    • The financial strain of operating and cooling data center gear. Additionally, some operators have reached the energy limit of what the grid can provide.
  • data center direct liquid cooling icon
    Emphasis on Sustainability
    • With growing importance on sustainability and benchmarks, IT teams need to use less energy and water, not more.
direct liquid cooling technology effect

How Direct to Chip Cooling can Help

Direct to chip cooling companies empower data center teams to do more with less. Less space. Less energy. Less cost.
  • Increase rack density 2 to 3 times, especially for high-TDP clusters vs. non-cooled data centers
  • Enable max GPU and CPU workload computing
  • Compared to traditional air conditioning, DTC is 30 – 50% more efficient, reducing energy consumption and floor space
  • Achieve PUE (Power Usage Effectiveness) of 1.04
  • DTC technology is simple to deploy and retrofitable to most server devices
  • Enhance thermal control, delivering predictable, consistent thermal performance. This prevents server throttling, sometimes needed with air cooling to keep the temperature down.

Key Benefits of Direct Liquid Cooling with Park Place

Improved Energy Efficiency/Lower Operational Costs 50–1000x more efficient than air cooling reducing energy consumption 25–30%, significant reduction in need for air conditioning
Minimized Environmental Impact Reduced energy consumption translates to a smaller carbon footprint contributing to sustainability goals
Support for High TDP (Thermal Design Power) CPUs and GPUs into thousands of watts per chip vs. 200–300x ceiling with air cooling
Increased Computing Density More efficient cooling allows for higher server densities in racks
Enhanced Performance and Reliability Components can operate at higher clock speeds without overheating, possibly extending their lifespan/reducing the frequency of replacements
Scalability Can be scaled to meet the demands of high-performance computing environments
Simple Installation Can be quickly applied to a singe server or an entire cabinet, with or without facility water

A Comprehensive Direct to Chip Cooling Solution

Park Place Technologies can serve as a single-vendor solution for your direct liquid cooling applications. This includes:

  • Procurement and installation of hardware for the direct to chip liquid cooling process.
  • Maintenance of server and direct to chip cold plate.
  • Ongoing performance and sustainability monitoring.

Park Place Technologies removes the complexities of the direct-to-chip liquid cooling journey – we serve as a single-vendor solution for the entire process.